CPAP Humidifier Water: Distilled, Tap, Limescale and a Clean Chamber
CPAP Humidifier Water: Distilled, Tap, Limescale and a Clean Chamber
A white crust on the base. Cloudy plastic. A faint smell. Water that runs out by 4am, or ends up in the tube. Your humidifier chamber does a lot of quiet work — here's how to look after it, especially in Britain's hard-water areas.
Everything about the water in your CPAP.
The part of your CPAP you breathe through.
Every night, your CPAP machine pushes air over a small tub of warm water before it reaches your mask. That humidified air is what stops your nose drying out, your throat getting scratchy and your mouth feeling like sandpaper in the morning. It's one of the most important comfort features on a modern CPAP machine.
But the humidifier chamber is also the part people think about least. It gets topped up in a hurry at bedtime, rinsed when someone remembers, and replaced only when it starts leaking. Meanwhile, water sits in it overnight, warm, every night of the year.
Why it matters in the UK
Much of Britain — particularly London, the South East and the East of England — has hard water, which leaves mineral deposits behind when it evaporates. You know it as limescale in the kettle. In a CPAP humidifier, the same thing shows up as a white crust on the base and a cloudy chamber.
On top of that, a warm, damp tub that isn't emptied and dried is exactly the kind of place where films and smells can develop. Neither is something you want between your machine and your lungs.
Do you even need to use it?
Humidification is a comfort feature, and how much you need is personal. On the AirSense 10, the humidity level can be set to Off or anywhere from 1 to 8. Some people sleep comfortably with little or no humidity; others find CPAP unbearable without it, particularly in winter when central heating dries the air. If you've never experimented, it's worth adjusting a step at a time over a few nights to find what suits you. Whatever you choose, if there's water in the chamber, it needs looking after.
The good news
Looking after a CPAP humidifier is simple once you know the rules, and most of them come straight from the manufacturer's user guide. This guide covers which water to use, how to deal with limescale, what to do about cloudiness, leaks and smells, and how to tell when it's time for a new chamber.
The examples here use the ResMed AirSense 10 and its HumidAir humidifier, the most common set-up in the UK. If you have a different machine, the principles are the same, but always follow your own user guide.
Know your water chamber.
Four parts of the chamber matter for care. Knowing where they are makes it obvious where problems start.
On a phone, swipe sideways to see the whole diagram.
The heater plate warms the water so it evaporates into the airflow. Because evaporation leaves minerals behind, this is where white deposits build up first in hard-water areas.
The fill line is there for a reason. ResMed's AirSense 10 user guide warns that overfilling can let water get into the device and the air tubing. On the AirSense 10's HumidAir, the guide gives a capacity of 380 mL to the maximum fill line.
The water itself should always be fresh. Water that has sat in a warm chamber since last night is no longer the water you poured in — some has evaporated, the minerals have concentrated, and it has been sitting warm and still for hours.
The seal keeps air and water where they should be. A cracked or torn seal is a common cause of leaks and lost humidity.
Distilled, boiled or straight from the tap?
The most common question about CPAP humidifiers — and the answer starts with your user guide.
ResMed's AirSense 10 user guide lists three recommended types of water in a section marked for France: distilled water, boiled tap water cooled to room temperature, and bottled water with a low mineral content. It also warns not to use non-sterile demineralised water intended for household use, and not to fill the humidifier with hot water. Other machines and other countries' guides can differ, so check the guide that came with your own machine.
In practice, many UK CPAP users choose distilled water, particularly in hard-water areas, because it contains very little mineral content to leave behind. That means less white crust on the heater plate and a chamber that stays clear for longer.
| Water | Listed in the AirSense 10 guide? | What to know |
|---|---|---|
| Distilled water | Yes | Very low mineral content, so the least scale. Widely available in UK supermarkets and chemists |
| Boiled tap water, cooled | Yes | Let it cool fully to room temperature. In hard-water areas, minerals remain, so expect more white deposits |
| Low-mineral bottled water | Yes | Check the label for a low mineral content |
| Non-sterile demineralised water for household use | No — the guide says not to use it | Often sold for irons and car batteries; not intended for breathing |
| Hot water | No — the guide says not to fill with hot water | Always let water cool first |
| Anything added to the water | No | No oils, fragrances or cleaning products — the chamber is for water only |
How to tell if your water is hard
If your kettle furs up with white scale, or your shower screen gets chalky marks, you almost certainly live in a hard-water area. Most UK water companies let you check your water hardness by entering your postcode on their website. In a hard-water area, choosing distilled water for your humidifier will save you a lot of descaling — and probably a few chambers.
Travelling?
Away from home, distilled water may be harder to find. Follow your user guide's alternatives, and always empty the chamber before transporting the machine — the guide asks you to make sure the humidifier is empty before you move the device, and not to use it with water in the humidifier on a plane. Our travel guide has more.
What's happening with your humidifier?
| What you notice | Usual cause | Read |
|---|---|---|
| White crust or powder on the base | Minerals from hard water | Problem 1 |
| Cloudy plastic, a film, or a smell | Water left standing, age, wear | Problem 2 |
| Water on the table or in the machine | Overfilling, a worn seal, tilting | Problem 3 |
| Chamber empty before morning | High humidity, leaks, a warm room | Problem 4 |
| Gurgling, water in the mask | Rainout in a cold tube | Problem 5 |
| Dry nose or mouth despite the humidifier | Setting too low, mouth leaks, unheated tube | Problem 6 |
A white crust on the base.
A chalky ring at the waterline, a gritty film on the heater plate, white specks that won't rinse off. Welcome to hard water.
Precautions first
Switch to distilled water if your user guide allows it. It's the simplest way to stop scale forming in the first place.
Don't top up — empty and refill. Topping up yesterday's water concentrates the minerals. The AirSense 10 guide asks you to empty the humidifier daily and wipe it with a clean, disposable cloth.
Remove deposits with diluted vinegar. ResMed's guide says to remove white powder deposits using a solution of one part household vinegar to ten parts water. Soak, then rinse very thoroughly with clean water so no vinegar smell remains.
Never scrape. Scratching the base or the plastic creates rough patches where deposits and films cling more easily.
Don't use kettle descalers or bathroom cleaners. The guide lists solutions not to use, including bleach, chlorine, alcohol and aromatic-based solutions. Stick to mild detergent and diluted vinegar.
Why it's worth dealing with
A little white powder isn't an emergency, but left alone it builds up into a rough, crusty layer. That layer is harder to clean, makes the chamber look cloudy, and gives films and residues more surface to cling to. Dealing with it early, with a gentle vinegar soak, is far easier than trying to remove months of build-up.
Which product helps
If the deposits won't shift, or the chamber has become cloudy or pitted, it's time for a new water chamber. ResMed's guide says to replace it if it has become cracked, cloudy or pitted.
Cloudy, slimy or smelly.
The plastic has lost its clarity. There's a slippery feel inside, or a faint stale smell when you open the lid. It's not something you want to breathe through.
What's going on
Water left sitting in a warm chamber — especially for more than a day — is the main cause. A film can form on the surfaces, and a damp chamber put back together without drying properly can start to smell. Over months, washing, heat and minerals also make the plastic cloudy, which is a normal sign of age.
Precautions first
Empty it every morning. Pour out any water left from the night, wipe it with a clean, disposable cloth as the guide suggests, and leave it open to air dry.
Wash it every week. The AirSense 10 guide says to clean the humidifier weekly in warm water with a mild detergent, rinse thoroughly and let it dry out of direct sunlight and heat.
Use the dishwasher correctly, if at all. According to ResMed's guide, the humidifier may be washed in a dishwasher on a delicate or glassware cycle, on the top shelf only, at no more than 65 °C. Hotter cycles can damage it.
Avoid scented and antibacterial products. The guide says not to use moisturising or antibacterial soaps, scented oils or aromatic solutions on the humidifier or tubing. They can damage the parts and leave residues.
Dry completely before reassembling. Moisture trapped under the lid or seal is a common cause of smells.
Our CPAP cleaning guide covers the whole machine, mask and hose routine.
Which product helps
If cleaning doesn't remove a smell or film, or the chamber stays cloudy, replace it. A hose cleaning brush kit is useful too: if the chamber has had a film, it's worth giving the tube a thorough scrub at the same time.
Leaks and spills.
A puddle on the bedside table. Water where it shouldn't be. Or a gurgle that seems to come from the machine itself.
Why it matters
Water in the wrong place isn't just messy. ResMed's guide warns that overfilling can let water into the device and the air tubing, and that placing the device on its side can let water into the machine. A CPAP machine is an electrical device, so this is worth taking seriously.
The usual causes
Overfilling. Filling above the maximum line is the most common cause.
A cracked or torn seal. The guide says to replace the humidifier if the seal is cracked or torn.
A cracked chamber. Small cracks, often from drops or dishwasher heat, can leak slowly.
Moving or tilting the machine with water inside. Even a short move across the room can slosh water where it shouldn't go.
Precautions first
Fill to the line, never above it. Fill the chamber away from the machine, then slide it back in carefully.
Use cool water, never hot, as the guide advises.
Let it cool before handling. The guide asks you to leave the humidifier to cool for ten minutes before handling it.
Keep the machine level, on a stable, flat surface below mattress height.
Empty before moving. Always empty the chamber before moving or packing the machine.
Unplug and dry. If water gets into the machine, unplug it, don't use it, and contact your supplier or the manufacturer for advice.
Which product helps
If the chamber or seal is cracked or worn, the fix is a replacement chamber.
The chamber runs dry before morning.
You wake at 4am with a parched throat and find the chamber bone dry.
Why it happens
The higher the humidity setting, the faster water evaporates. A big mask leak also uses more water, because more air is flowing through the system. A warm, dry bedroom — central heating on high in winter — can increase how much humidity you need. And longer nights simply use more water.
Precautions first
Fill to the maximum line every night — but not above it.
Fix any mask leak. High leak means more airflow and more evaporation. Check the leak figure in your machine or app. Our CPAP data guide explains what's normal.
Try a slightly lower humidity setting. On the AirSense 10, humidity can be set to Off or from 1 to 8. A step down may make the water last the night without leaving you dry.
Check the room. If the radiator is right next to the bed or the heating is on all night, the air may be very dry.
Expect to change settings with the seasons. Many people need more humidity in winter, when the heating dries the air, and less in summer. A setting that was perfect in July may leave you dry in January — or with a full tube of water.
Don't run the machine empty. If you find the chamber dry, refill it with cool water once the humidifier has cooled down.
Which product helps
A heated tube keeps the air warm to the mask, which lets you find a comfortable humidity setting without rainout — and often means you don't need to run the humidifier as hard.
Water in the tube — and in your mask.
A gurgle as you breathe, droplets in the mask, a splash on your face in the night. This is rainout.
Why it happens
Warm, humid air from the chamber travels through the tube. If the tube is in a cold room, the air cools on the way and the moisture condenses into water — just like condensation on a cold window. It's most common in British bedrooms in winter.
Precautions first
Turn the humidity down a step if you're getting water in the tube or mask.
Keep the machine lower than the bed so any water runs back towards the machine rather than into your mask.
Warm the bedroom a little if you can, and keep the tube off cold surfaces such as a window sill or outside wall.
Route the tube under the duvet edge or over the headboard to keep it a little warmer.
Our winter CPAP guide covers rainout in more depth.
Which product helps
A heated tube is the most effective fix, because it keeps the air warm all the way to the mask. The AirSense 11 needs its own ClimateLineAir 11 tube. A fleece hose cover adds insulation, and many people use one over a heated tube for extra comfort.
Still waking with a dry nose or mouth.
The humidifier is full, it's switched on — and you still wake up parched.
Why it happens
The setting may be too low for your room and the season. Your mouth may be open with a nasal mask, so humidified air rushes straight out. A mask leak may be sending air across your face. Or you may have turned the humidity down to stop rainout, and swapped one problem for another.
Precautions first
Increase humidity one step at a time, giving each setting a few nights.
Check for mouth breathing. A dry mouth with a nasal mask usually means air is escaping through the mouth. A full face mask, or advice from your clinic, may help.
Fix leaks by refitting the mask lying down and replacing a worn cushion.
Use a heated tube so you can run higher humidity without rainout.
Drink water during the day, and go easy on alcohol in the evening, which is drying.
If dryness, nosebleeds or a blocked nose continue, speak to your sleep clinic or GP. Our side effects guide covers dry mouth and nose problems in detail.
Which product helps
For mouth breathers, a full face mask keeps the humidified air where it belongs. Combine it with a heated tube for the most comfortable air.
Two minutes a day, ten minutes a week.
Let the humidifier cool, remove it, pour away any water left, wipe it with a clean, disposable cloth, and leave it open to air dry away from direct sunlight and heat.
Fill with fresh, cool water of the type your guide recommends, up to the maximum line and no further. Slide the chamber back in carefully, keeping the machine level.
Wash in warm water with a mild detergent, rinse thoroughly and dry completely. Or use the dishwasher on a delicate or glassware cycle, top shelf only, at no more than 65 °C.
Soak in one part household vinegar to ten parts water, then rinse very thoroughly with clean water and dry.
Hold the chamber up to the light. Look for cracks, cloudiness, pitting, and a seal that's cracked or torn. Any of these means it's time to replace it.
Signs it's time for a new chamber.
ResMed's guide uses the chamber's condition, rather than a fixed date, to decide when to replace it. Replace your chamber if you see any of these.
Some people also replace their chamber at regular intervals, or when their supplier or clinic recommends it. If you're in a hard-water area, you may find yours needs replacing sooner. Our replacement schedule covers every CPAP part.
Consider keeping a spare. A spare chamber means a crack or a leak at bedtime doesn't cost you a night of comfortable therapy. It also makes the weekly wash easier: use one while the other dries completely. Rotating two chambers is a simple habit that keeps both in better condition, because neither is ever put back damp.
Using an AirSense 11? Its water chamber is different from the AirSense 10's, so make sure you choose the right one. Contact us if you're not sure which chamber fits your machine.
Five humidifier myths.
Quick answers on CPAP humidifier water.
Do I have to use distilled water in my CPAP humidifier?
Follow your machine's user guide. ResMed's AirSense 10 guide lists distilled water, boiled tap water cooled to room temperature, and low-mineral bottled water. Many UK users choose distilled water, especially in hard-water areas, because it leaves the fewest mineral deposits.
Can I use tap water in my CPAP?
Check your user guide. The AirSense 10 guide lists boiled tap water cooled to room temperature as an option. In hard-water areas, tap water leaves more white deposits, so you may need to descale more often or replace the chamber sooner.
How do I remove limescale from my CPAP water chamber?
ResMed's guide recommends removing white powder deposits with one part household vinegar to ten parts water, then rinsing thoroughly. Don't scrape the chamber or use kettle descalers, bleach or harsh cleaners.
How often should I clean my CPAP humidifier?
Empty it daily and wipe it with a clean, disposable cloth, then wash it weekly in warm water with mild detergent. The AirSense 10 humidifier can also go in the dishwasher on a delicate or glassware cycle, top shelf only, at no more than 65 °C.
When should I replace my CPAP water chamber?
Replace it if it's leaking, cracked, cloudy or pitted, or if the seal is cracked or torn. These are the signs ResMed's AirSense 10 guide gives. In hard-water areas, chambers may need replacing sooner.
Why does my CPAP humidifier run out of water overnight?
Usually because the humidity setting is high, there's a mask leak, or the bedroom is warm and dry. Fill to the maximum line, fix any leak and try a slightly lower humidity setting. A heated tube can help you find a comfortable balance.
Can I leave water in my CPAP humidifier during the day?
It's best not to. The AirSense 10 guide asks you to empty the humidifier daily and wipe it dry. Water left standing in the chamber encourages films, smells and mineral deposits.
More UK-specific CPAP guidance.
This guide is general information, not medical advice. Always follow the user guide supplied with your own CPAP machine and humidifier, as recommendations differ between models and countries. Unplug the machine before cleaning, never immerse the machine or power supply in water, and make sure all parts are dry before use. If water gets into your machine, stop using it and seek advice.
Never adjust your prescribed pressure settings yourself. If dryness, nosebleeds or a blocked nose continue, speak to your sleep clinic or GP. Information from ResMed user guides is summarised and may not apply to every model or region. ResLab compatible products are not manufactured by or affiliated with ResMed.
AirSense™, AirCurve™, ClimateLineAir™, HumidAir™ and ResMed™ are trademarks of ResMed Ltd.